Loadcells.co.uk focuses on the UK product range of Interface Force Ltd. We offer a complete range of class leading load cells, torque transducers and instrumentation to fill all of your force and torque measurement needs.

Use our live chat service to speak to an operator directly

Signal Conditioning & Amps Products

ITA-1 In Line Amplifire - In-line analogue strain gauge amp.

ITA-1 In Line Amplifire

In-line analogue strain gauge amp.

 The ITA-1 (known in this office as the Click-R Clack-R) is an analogue strain gauge amplifier that connects to your sensor in line via a 5-pin, M12 connector. It’s used to convert the millivolt signal from your sensor into an analogue signal for your display or DAQ. The ITA-1 can be connected to any force, strain, torque or pressure sensor that supplies a millivolt output signal.  Output can be either voltage or current.

The ITA-1 is supplied factory configured when supplied with an Interface load cell or torque transducer, but set up can be modified by the user using the tare and scale cables 

View product

SGA Signal Conditioner  - AC/DC Millivolt to Analog Converter

SGA Signal Conditioner

AC/DC Millivolt to Analog Converter

The SGA-A is a high-performance strain gauge signal conditioning amplifier that’s idea for use with load cells, force, pressure and torque sensors. 

The SGA-A is versatile amplifier that can provide excitation voltage to up to four transducers from a single channel. Output signal can be selected from 0-20mA, 4-20mA, 0-10V, 0-5V, ±5 V or ±10 V

The SGA is supplied in a IP67 environmentally sealed case, making it suitable for use away from the workshop or laboratory 

View product

SY008 Automotive Amp - Signal Amp for Automotive Aplications

SY008 Automotive Amp

Signal Amp for Automotive Aplications

The SY008 is a strain gauge amplifier that is designed to meet the specific needs of automotive applications. The SY008 is housed in a die cast Aluminium case that is rated to IP65 standards, makes this a very robust and reliable amplifier.

Both the Voltage out and Current out versions offer high output accuracy with the additional convenience of easy set-up span and zero adjustments 

View product

SY028 Trip - Load Cell Amp with High & Low Trips

SY028 Trip

Load Cell Amp with High & Low Trips

The SY028 is load cell amplifier is a level indicator used to monitor high and low load levels. It's the only amplifier with an internal alarm function that allows it ro determine if a load is within a accpetable  pre-set range

View product

SY038 Load Cell Amp - Load Cell Signal Amplifier

SY038 Load Cell Amp

Load Cell Signal Amplifier

The SY038 is compact, DIN rail mountable strain gauge amplifier. Featuring user selectable sensitivity ranges, the SY038 is capable of accepting signals from up to four 350ohm load cells.

There are sixteen user selectable transducer ranges, from as low as 0.25mV/V to 4mV/V. Non interactive zero and span adjustment gives up to +/-20% adjustment.  

Please note that if you are intending to use the SY038 with a +/- 4mV/V load cell will require an 8 mV/V input special version. Please e-mail info@interface.uk.com for details

NOTE: This only applies to Current versions

 

View product

SY046 Signal Amp with Tare - Load Cell Amplifier with Digital Tare

SY046 Signal Amp with Tare

Load Cell Amplifier with Digital Tare

The SY046 strain gauge amplifier is an analogue amplifier with the digital gain advantages, it can excite up to 4 x 350Ω bridge transducers and provides either a 4 – 20mA, 0 – 5V or 0 – 10V output with a remotely triggered zero offset. This feature is of great value when load cells are difficult to access or other strain-gauged components have been installed in difficult environments. The display is very useful during set up and calibration.

The SY046 is supplied with a user configurable digital gain (gains of 1, 2, 4 or 8). This can be very useful if a small load is to be monitored with a high dead load offset e.g. connected to a 1 tonne cell with a digital gain of 8 the input could accept the full 0 – 1 tonne range while the output covers a range of 125kg anywhere within the input span.

The zero is reset by means of a positive pulse or by a remote switch to the V+ or GND. A wide range of mV/V sensitivities is accepted (please specify) and there is a +/-20% adjustment at the calibration stage of the set up. A 5way switch selects if you want the display to show the output or a % of the full scale, if it is uni-polar or bipolar, the input sampling rate and what gain setting you require. The unit is supplied in an ABS DIN rail mounted case with a 3digit display.

View product

Random Product

9320 TEDS Indicator
9320 TEDS Indicator
Hand Held Indicator

 

The 9320 Portable Strain Display Load Cell/Force transducer readout is a microprocessor based portable instrument designed to

View product View our product range